When Not to Reset a Tripped Circuit Breaker
Do not touch the consumer unit if you notice any of the following:
- Burning smell, smoke, scorch marks, or buzzing/crackling sounds.
- Water leaking into the consumer unit, sockets, or light fittings.
- Cracked, hot, or damaged consumer unit casing.
- Smell of gas — do not operate electrical switches; call the National Gas Emergency Service on 0800 111 999.
Never remove the consumer unit cover or tamper with supplier fuse seals. Call a qualified electrician immediately.
How to Reset a Tripped MCB or RCD in the UK
Miniature circuit breakers (MCBs), RCBOs, and residual current devices (RCDs) trip to protect against overloads and earth faults. Run through this check once:
- Find the consumer unit: Check under stairs, in a hallway cupboard, utility room, or garage near the meter. Use a torch if lighting is out.
-
Identify the tripped device: Open the front flap only. Look for a switch in the OFF (down) or central tripped position:
- Single MCB or RCBO: Fault is isolated to that specific circuit (such as sockets or lighting).
- RCD (wider switch with a T or Test button): A fault on one of the circuits protected by that RCD caused it to trip.
- Unplug appliances on that circuit: Unplug appliances from wall sockets rather than only toggling socket switches, and switch off affected light switches.
- Reset a single tripped MCB: Push firmly down to OFF, then firmly up to ON. If it holds, plug appliances back in one at a time; the appliance that trips it again has a fault and should stay unplugged.
-
Reset a tripped RCD:
- Turn OFF the smaller MCBs grouped alongside that RCD.
- Push the RCD firmly down to OFF, then up to ON.
- Switch the MCBs back ON one at a time with a few seconds between each. If flipping a specific MCB trips the RCD, leave that MCB OFF and restore the remaining circuits.
- Stop after one attempt if it trips immediately: Repeatedly resetting a breaker or RCD can damage the device and points to a fixed wiring or appliance fault needing testing.
24/7 Emergency Callout Prices in Croydon, Sutton & Wallington
Current UK time: Thursday, 15:29. We operate 24 hours a day, 7 days a week across Croydon, Sutton & Wallington, with our currently active rate highlighted below:
| Callout Window | Fixed Callout Fee | What's Included |
|---|---|---|
| Daytime Emergency Callout (Mon–Fri, 08:00 – 18:00) Current Rate | £120 No VAT | Rapid attendance, fault diagnosis/make-safe & up to 60 mins labour included |
| Out-of-Hours Callout (18:00 – 08:00, Weekends & Bank Holidays) | £150 No VAT | 24/7 urgent attendance, fault diagnosis/make-safe & up to 60 mins labour included |
No VAT to pay: Unlike VAT-registered national call-centres, there is 0% VAT added to our prices. Most tripped-breaker and urgent electrical faults are diagnosed and made safe within the included first hour. If replacement parts or larger follow-on repairs are needed, we agree a clear fixed price (such as our £250 half-day or £450 full-day booked rate) before proceeding. View all pre-booked & EICR prices →